Equipment / Greasing Equipment & Accessories / Automatic Lubrication / Graco Trabon MSP & MHH Divider Valves
GracoA divider valve system is series-progressive. Grease enters the valve and is passed from one section to the next in a fixed sequence, so every section has to move before the cycle completes. That single characteristic is the whole argument for the architecture: if the valve is cycling, every point on that circuit is receiving grease, and you can prove it by watching one indicator.
| Manufacturer part number | 562733 |
|---|---|
| Discharge per piston stroke (cm³) | 0.080 |
| Maximum working pressure (psi) | 3500 |
| Maximum cycle rate (cycles/min) | 60 |
| Maximum operating temperature (°f) | 350 |
Specification published by Graco. Part numbers confirmed at order.
| Valve | Material | Sections |
|---|---|---|
| Trabon MSP divider valve | Stainless steel | 3 section |
| Trabon MSP divider valve | Stainless steel | 4 section |
| Trabon MSP divider valve | Stainless steel | 5 section |
| Trabon MSP divider valve | Stainless steel | 6 section |
| Trabon MSP divider valve | Stainless steel | 7 section |
| Trabon MSP divider valve | Stainless steel | 8 section |
| Trabon MSP divider valve | Stainless steel | 10 section |
The trade-off is confirmation versus isolation. In a divider valve circuit, a blockage anywhere stops the whole train, which sounds like a disadvantage and is in fact the reason the architecture is trusted on critical machinery: a fault cannot hide. In a parallel injector system, a blocked line quietly starves one point while everything else looks normal.
So the choice comes down to what failure you can least afford. If losing one bearing is survivable and stopping the machine is not, injectors suit. If a single unlubricated point is a catastrophic failure, and a stopped circuit that raises an alarm is preferable, divider valves suit. Heavy fixed plant, crushers, conveyors, presses and critical drives are typically divider valve territory for exactly that reason.
Section count from 3 to 10 sets how many outlets one valve serves. Each section delivers a proportioned output, and cross-port bars let adjacent outputs be combined to give a heavier dose to a point that needs it. That is how one valve serves points of quite different sizes without needing a valve per point.
Larger installations use a master valve feeding secondary valves, which is how a single pump can serve a hundred points with the whole chain still provable from one indicator at the master.
An indicator that shows the valve is cycling turns lubrication from an assumption into an observation. A maintenance fitter walking past can confirm the circuit is working in a second, and the indicator can be monitored so a stalled valve raises an alarm rather than being discovered after a bearing failure. On plant where the lubrication circuit is inside a guard or up a structure, this is often the difference between a system that is maintained and one that is assumed to be fine.
When a series-progressive circuit blocks, pressure rises until something gives. A relief valve gives the system somewhere to go, and an automatic relief indicator makes the event visible so the fault is investigated rather than repeating. Specifying relief protection is not optional on a high-pressure grease circuit; it is what stops a blockage becoming a burst line and a stopped machine.
MSP valves in stainless steel suit wash-down, coastal, mining and chemical environments where the valve body would otherwise corrode. On plant that is high-pressure washed every shift, the valve and its fittings deteriorate from the outside long before anything inside wears.
Divider valve systems are engineered: proportioning, grouping, master and secondary layout, relief protection and monitoring all have to be worked out against the machine. TWSA designs, installs, commissions and services automatic lubrication systems on fixed plant and heavy mobile equipment.
Every one of these ranges is quoted, not listed at a shelf price, because the right configuration depends on your fluids, your bay layout and the plant you maintain. Send TWSA your fluid list, your bay count and a photo of the existing setup and we will come back with a specified quote.
No prices on the site, on purpose. The Graco Trabon MSP & MHH Divider Valves is quoted with supply, installation and servicing scoped to your bays and workload.
Building a list? Add several items and send them as one request.
Quote this item on its own Product sheet · 1 page (PDF) Full brochure · specifications (PDF) Response within one business day, from a technician.Prefer to talk it through?
1300 871 711